603 2 3 door swing exception 2.
Overlap of clear floor space ada.
Technical memorandum 2013 17 water closet clearance overlap the door swing is allowed to overlap the clearance for a water closet and a lavatory in a toilet room as long as there is a 30 760 mm x 48 1220 mm clear floor space beyond the arc of the door.
The required clearance around the water closet shall be permitted to overlap the water closet associated grab bars dispensers sanitary napkin disposal units coat hooks shelves accessible routes clear floor space and.
The cbc 1118b 4 1 indicates that the clear floor space for wheelchairs may be part of the knee space required under some objects which allows the clear floor space to extend under the 27 clearance required under sinks cbc fig.
Turning space complying with 304 shall be provided within the room.
An accessible lavatory may overlap the clear floor space at the back wall as long as a minimum 18 inches 455 mm clearance is maintained between the centerline of the water closet and the nearest edge of the lavatory.
Clear floor space is required at each accessible element including storage cabinets drinking fountains and other fixtures and electrical outlets.
Required clear floor spaces clearance at fixtures and turning space shall be permitted to overlap.
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space.
Refer to figure e.
Clear floor space is required at each accessible element including storage cabinets drinking fountains and other fixtures and electrical outlets.
Clear floor space at elements.
The required clearance around the water closet shall be permitted to overlap the water closet associated grab bars dispensers sanitary napkin disposal units coat hooks shelves accessible routes clear floor space and clearances required at other fixtures and the turning space.
Doors shall not swing into the clear floor space or clearance required for any fixture.
Clear floor spaces can overlap where elements are in close proximity.
Required clear floor spaces clearance at fixtures and turning space shall be permitted to overlap.
Clear floor spaces can overlap where elements are in close proximity.